As per IS 1293 - 1988 clause - 21. The socket outlet are
mounted in normal used & the pulling force is applied in
the direction similar to the normal used. The socket
outlet is held in a vertical plane & the pulling on the
projecting part of it downmost . The applicable force
should be applied as per table given below to have
necessary withdraw the plug from the socket outlet.
Current In ( A ) |
Force In ( N ) |
|
Min |
Max |
6 |
3.0 |
60 |
16 |
4.0 |
80 |
|
|